Due to global supply chain constraints lead times for shipments may be delayed. We are actively working with our suppliers to mitigate shortages and improve lead times. If you have questions, please contact your AMRtechnologiesInc. representative at 1-800-213-0227 or submit your question AMRtechsolar@gmail.com
Schneider Electric Conext CL 25kW Inverter PVSCL25NA301
CL36 String Inverter IEC
CL-60E String Inverter
The ideal solution for decentralized power plants and large commercial buildings
Schneider Electric 25kW 3-PH Grid-Tied Inverter - PVSCL25NA301
Schneider-Electric, Conext CL-25000-NA, Grid-Tied TL Inverter, 3-PH, 25kW, 277/480Vac, 60Hz, 1000Vdc, 4 String input, Per channel, (add fuses) 2 MPPT, DC Switch, AFCI, Â AC-SPD, DC-SPD, Integrated data logger, 10 yr. Warranty, Model-Optimum+AFD, (2 boxes), PVSCL25NA301
The Conext CL Series is a new line of three phase string inverters designed for high efficiency, maximum flexibility and easy installation and service. Electrolyte-free design with Schneider Electric’s rigorous reliability test procedures improve the long term reliability. Five configuration options of integrated wiring box allow for easy, flexible and low cost installations. Decentralised architecture, full grid support features and system capability together with Schneider Electric’s broad range of medium voltage products make Conext CL the ideal choice for medium and
large PV plants. Backed by Schneider Electric’s global service infrastructure, leading manufacturing facilities and its expertise in energy management, the Conext CL Series is the inverter you should trust for quality and reliability.
Features
-
Reliable & Flexible - Robust design through rigorous Multiple Environmental Over Stress Testing (MEOST), Highly Accelerated Life Test (HALT) and Temperature Humidity and Bias testing (THB). Electrolyte-free design to guard against dried cap issue and help to improve long term reliability. Designed and qualified for applications in tropical environments through salt fog testing and use of conformal coating. Five options of wiring box (base, essential, essential+, optimum and optimum+) to fit different applications. 10° - 90° installation angle to allow for flexible mounting. CL 18000NA supporting both 600 V and 1000 V applications.
-
Flexible & Easy to Service - Touch-safe fuse holder available for easy and protective fuse replacement. Easily replaceable fan, easy firmware upgrade via USB. Both DC and AC Surge Protection Device (SPD) with included monitoring to help to protect inverter from lightning threat (optimum model). Detachable inverter to allow for easy installation and upgrades. Light weight with integrated handle for 2 persons installation. Both bottom and side cable entry to allow for flexible installation.
- Higher ROI - Warranty from a trusted partner with 178 years of experience. World leader in industrial power drives, UPS and electrical distribution. Strong service infrastructure worldwide to support your global needs. High conversion efficiency: 98.4% peak efficiency, 98.0% CEC efficiency. Great value for money: integrated wiring box saves the cost of external DC combiner box. Overpaneling capability to allow for maximizing energy harvest.
We’re honored to announce that Schneider Electric’s CL-60 is named as a Top Performer in PV Evolution Labs’ (PVEL) PV Inverter Reliability Scorecard. The PVEL PV Inverter Reliability Scorecard is designed to provide with insight into long-term reliability of inverters. CL-60 has been identified as a top performer in multiple tests including MPPT efficiency, conversion efficiency, energy harvest, and power thermal cycling.
Insight – One Platform You Need for Energy Management
Advanced Cybersecurity
Insight is in compliance with international cybersecurity standards. Encrypted communication and storage of user information ensure user’s site access and information are always protected and the data is stored securely.
Access from Anywhere at Any Time
Insight is available through our local, cloud, and mobile interfaces.
Schneider Electric 25kW 3-PH Grid-Tied Inverter - PVSCL25NA301
Schneider-Electric, Conext CL-25000-NA, Grid-Tied TL Inverter, 3-PH, 25kW, 277/480Vac, 60Hz, 1000Vdc, 4 String input, Per channel, (add fuses) 2 MPPT, DC Switch, AFCI, Â AC-SPD, DC-SPD, Integrated data logger, 10 yr. Warranty, Model-Optimum+AFD, (2 boxes), PVSCL25NA301
Features
- Reliable & Flexible - Robust design through rigorous Multiple Environmental Over Stress Testing (MEOST), Highly Accelerated Life Test (HALT) and Temperature Humidity and Bias testing (THB). Electrolyte-free design to guard against dried cap issue and help to improve long term reliability. Designed and qualified for applications in tropical environments through salt fog testing and use of conformal coating. Five options of wiring box (base, essential, essential+, optimum and optimum+) to fit different applications. 10° - 90° installation angle to allow for flexible mounting. CL 18000NA supporting both 600 V and 1000 V applications.
- Flexible & Easy to Service - Touch-safe fuse holder available for easy and protective fuse replacement. Easily replaceable fan, easy firmware upgrade via USB. Both DC and AC Surge Protection Device (SPD) with included monitoring to help to protect inverter from lightning threat (optimum model). Detachable inverter to allow for easy installation and upgrades. Light weight with integrated handle for 2 persons installation. Both bottom and side cable entry to allow for flexible installation.
- Higher ROI - Warranty from a trusted partner with 178 years of experience. World leader in industrial power drives, UPS and electrical distribution. Strong service infrastructure worldwide to support your global needs. High conversion efficiency: 98.4% peak efficiency, 98.0% CEC efficiency. Great value for money: integrated wiring box saves the cost of external DC combiner box. Overpaneling capability to allow for maximizing energy harvest.
Mechanical Data
Mechanical Data |
|
Dimensions: |
28.10 x 26.50 x 10.50 inches |
Wiring Box Dimensions: | 14.20 x 26.50 x 10.50 inches |
Weight: | 119.00 lbs |
Power Consumption at Night Time: | < 3.0 W |
Enclosure Rating: | Type 4 (Electronics) / Type 3R (Rear Portion) |
Cooling: | Fan Cooled |
Ambient Air Temperature for Operation: | -25°C to +60°C |
Max. Operating Altitude w/o Derating: | 6560 Feet |
Relative Humidity: | 4-100% Condensing |
Noise Emission: | < 58 dBA |
Embedded Data Logger: | Yes |
User Interface: | Graphic Display, Key Pad |
Communication Interface: | RS485 (MODBUS RTU), Ethernet / MODBUS TCP (Ethernet), USB, dry contact and key pad |
Monitoring: | SunSpec Alliance profile, Surge Protection Device (SPD) and Arc Fault Detection (AFD) monitoring available with device |
Remote Power Off: | Yes |
Certifications: | UL1741. IEEE 1547.1, CSA C22.2 107.1-01, FCC Part 15 |
Electrical Data |
|
Full Power MPPT Voltage Range: | 500-800 Volts |
Operating Voltage Range: | 250-1000 Volts |
Max. Input Voltage, Open Circuit: | 1000 Volts |
Number of MPPT/Strings per MPPT: | 2/4 |
Max. DC Input Current per MPPT: | 26.5 Amps |
Max. Array Short Circuit Current per MPPT: | 36.0 Amps |
Nominal DC Input Power: |
26.5 kW |
Max. DC Input Power per MPPT: | 15.9 kW |
DC Connection (in the wiring box): |
Bottom and side conduit/cable entry, Base Model: Spring Cap Clamp Connector, Essential Model and Optimum Model: Fuse Holder |
Rated Output Power: | 25.0 kW |
Max. Apparent Power: | 25.0 kVA |
Nominal Output Voltage: | 277/480 V |
AC Voltage Range: | 244-305 V / 422-528 V |
Frequency: | 60 Hz |
Max. Output Current: | 33.0 A |
Nominal Continuous Output Current: | 30.1 A |
Total Harmonic Distortion: | < 3% |
Power Factor (Adjustable): | 0.8 Lead to 0.8 Lag |
AC Connection (in the wiring box): | Bottom and side conduit/cable entry, spring cage clamp |
Peak Efficiency: | 98.4% |
CEC Efficiency: |
98.0% |
This Product does not include Tax and shipping costs. International shipping is subject to regulations and Import Taxation of Country of destination.
Tel: (+506) 7037-8077 or Toll Free: 1(800) 2130227