MAGNUM ENERGY-DIMENSIONS-CE-6 Solar Charge Controller
MAGNUM ENERGY-DIMENSIONS-CE-6 Solar Charge Controller
Output Current
6 A
|
MPPT
No
|
Power Consumption
< 4 mA
|
System voltage
12 V (24 V)
|
Power consumption
< 4 mA
|
Open circuit voltage solar module (at minimum operating temperature)
< 47 V
|
Module current
6A
|
Load current
6 A
|
Reconnection voltage (LVR)
12.4 to 12.7 V (24.8 V to 25.4 V)
|
Deep discharge protection (LVD)
11.2 V to 11.6 V (22.4 V to 23.2 V)
|
End-of-charge voltage
13.9 V (27.8 V)
|
Boost charge voltage
14.4 V (28.8 V)
|
Set battery type
gel
|
Charge current
6 ADC
|
Ambient temperature
-13° F to 122° F (-25° C to +50° C)
|
Terminal (fine/single wire)
AWG 12 / 9 (4 mm2 / 6 mm2 )
|
Degree of protection
IP 31
|
Dimensions (width x height x depth)
5.7” x 3.9” x 1.2” (145 mm x 100 mm x 30 mm)
|
Shipping dimensions (width x height x depth)
5.7” x 3.9” x 1.2” (147 mm x 100 mm x 31 mm)
|
Weight
.33 lb (150 g)
|
Shipping weight
.35 lb (160 g)
|
Product Characteristics
Model No. |
|
|||||
---|---|---|---|---|---|---|
Electrical Data | ||||||
Max. Solar Panel Open Circuit Voltage |
|
|||||
Nominal System (Battery) Voltage |
|
|||||
Maximum Output Load Current |
|
|||||
Self-Consumption |
|
|||||
General Data | ||||||
Dimensions (H/W/D) |
|
|||||
Weight |
|
|||||
Terminals (Wire Size) |
|
|||||
Equalize Charging Voltage |
|
|||||
Boost Charging Voltage |
|
|||||
Battery Type | GEL, VLA | |||||
Operating Temperature Range | -25 ~ +50 °C | |||||
Communication Ports | USB | |||||
Display | LED | |||||
Protection Features | ||||||
Protection Features | Short Circuit Protection, PV Reverse Polarity Protection, PV Overvoltage Protection, PV Reverse Current Protection at Night, Battery Reverse Polarity Protection, Overload Protection, Over Charging Protection, Over Discharging Protection, Over Temperature Protection |
AMRtechnologies Inc. Solar & Electrical Systems
Tel: (+506) 7037-8077 or Toll Free: 1(800) 2130227
Solar Systems in United States & Latin America