Due to global supply chain constraints lead times for shipments may be delayed. We are actively working with our suppliers to mitigate shortages and improve lead times. If you have questions, please contact your AMRtechnologiesInc. representative at 1-800-213-0227 or submit your question AMRtechsolar@gmail.com
CYBOENERGY-ON/OFF GRID CIM 1200E/T
Take matters into your own hands and avoid power outages by creating your own energy!
Enjoy the 24/7 Security of Having Your Own Solar System that can produce clean energy by day and automatically switch to grid use at night and battery backup during grid outages.
- On-Grid or Off-Grid Mode
- Specially Designed to Provide Backup Power when the Grid is Down
- Four DC Input Channels for Solar or Battery Input
- Over Discharge Protection for 48V Lead-Acid Batteries
- Pure Sinewave AC Output
- MPPT for Each Solar Panel
- Outdoor or Indoor Mounting
- Made in U.S.A
Each CyboInverter (CIM-1200E/T) can connect to four solar, battery, or wind DC sources and produce 1250W, 230V, 50Hz AC to the grid when grid is on, or 230V AC to an off-grid circuit to run AC loads. When the grid is on, the inverter works like a regular on-grid inverter that meets UL1741 and IEEE1547 standards including: over and under voltage shutdown; over and under frequency shutdown; and anti-islanding. When the grid is down, the inverter will shutdown immediately and then send a test signal from its off-grid output port to check the status of the connected off-grid AC circuit. If there is no AC present and an AC load is detected, it will generate AC to power the load.
In the off-grid mode, when the inverter detects the grid is back on, it will stop powering the load. After a 5-minute UL mandatory wait, the inverter will send AC power to the grid again. When the grid is on, the inverter works like a regular on-grid inverter that meets UL1741 and IEEE1547 standards including: over and under voltage shutdown; over and under frequency shutdown; and anti-islanding.
When the grid is down, the inverter will shutdown immediately and then send a test signal from its off-grid output port to check the status of the connected off-grid AC circuit. If there is no AC present and an AC load is detected, it will generate AC to power the load. In the off-grid mode, when the inverter detects the grid is back on, it will stop powering the load. After a 5-minute UL mandatory wait, the inverter will send AC power to the grid again.
The drawing shows 2 on-grid and 1 on/off-grid CyboInverters daisy-chained as a group.