Acclima-Digital True TDR-305N Soil Moisture Sensor (SDI-12)
- Vendor
- Acclima
- Regular price
- $386.40
- Sale price
- $386.40
- Regular price
-
- Unit price
- /per
Adding product to your cart
Due to global supply chain constraints lead times for shipments may be delayed. We are actively working with our suppliers to mitigate shortages and improve lead times. If you have questions, please contact your AMRtechnologiesInc. representative at 1-800-213-0227 or submit your question AMRtechsolar@gmail.com
Acclima-Digital True TDR-305N Soil Moisture Sensor (SDI-12)
Product Summary
Completely integrated TDR soil water content sensor (a.k.a., soil moisture sensor, probe, or meter) accurately yields VWC and BEC/PWEC with a high-speed 300 pico-second rise time for a detailed wave form analysis. Designed for high EC tolerance when taking readings. A great measurement solution for soils with exceedingly high salt levels.
The TDR-305N is a modified version of the TDR-310N. The very short waveguide allows this sensor to make very shallow measurements and to be used in higher conductivity environments with a sacrifice in total measurement volume. It has a high voltage waveform output, which makes it effective in taking measurements when the soil electrical conductivity is high. It also consumes more power than the TDR-315H. It is a complete integrated time domain reflectometer that combines ultrafast waveform generating and digitizing functions with a precision 5 picosecond resolution time base and highly sophisticated waveform digitizing and analyzing firmware that provides true time domain analysis of soil-propagated waveforms. Its form factor is designed for easy vertical installation in an augured hole using a 34 mm flat-bottomed auger.
It mates with a 1” schedule 40 PVC pipe that acts as a handle in its installation to any desired depth. It provides reading data through a 3-wire SDI-12 interface and is compatible with any data recorder that is compliant with SDI-12 version 1.4 and earlier.
Key Features
- Housing designed for easy bore hole installation at any depth
- Shorter waveguides are great for “check and go” type applications such as mobile readings on golf greens, other turf management, or limited space environments
- Ideal for high conductivity environments
- Soil Smart analysis works with all mineral soil types
- SDI-12 Interface
- 3-element 5 cm stainless steel waveguide
- 5 m or 10 m 3-conductor waterproof cable (standard)
- Waterproof Epoxy-filled Housing
- 20% to 80% Incident Wave Rise Time: 300 ps
- Waveform Digitizing Resolution: 5 ps
- Incident Wave Amplitude: 2.3 V
Measurement Functions
- Volumetric Water Content: 0% to 100%
- Medium Permittivity: 1 to 85
- Medium Bulk Electrical Conductivity: 0 to 6000 µS/cm
- Medium Temperature: -40 to +55 degrees C
- Pore Water EC (Hilhorst Model): 0 to 55000 µS/cm
Description
The TDR-305N is a 5cm waveguide version of the TDR-310N. The shorter waveguide allows this sensor to make very shallow measurements and to be used in significantly higher conductivity environments. It also has a much higher amplitude waveform than the H-series sensors, which consumes more power but makes it very effective in taking measurements in challenging soil environments. Being part of the Soil Smart Series means that its advanced waveform analysis works with all mineral soil types. It is a complete integrated time domain reflectometer that combines ultra-fast waveform generating and digitizing functions with a precision 5 pico-second resolution time base and highly sophisticated waveform digitizing and analyzing firmware that provides true time domain analysis of soil-propagated waveforms.
Its form factor is designed for easy vertical installation in an augered hole using a 34 mm flat-bottomed auger. It mates with a 1” schedule 40 PVC pipe that acts as a handle in its installation to any desired depth. It provides reading data through a 3-wire SDI-12 interface and is compatible with any data recorder that is compliant with SDI-12 version 1.4 and earlier.
The shorter waveguide allows this sensor to make very shallow measurements and to be used in significantly higher conductivity environments.
Features
- Housing designed for easy bore hole installation at any depth
- Shorter waveguides are great for “check and go” type applications such as mobile readings on golf greens, other turf management, or limited space environments
- Ideal for high conductivity environments
- Soil Smart analysis works with all mineral soil types
- Incident Wave Amplitude: 2.3 V
- 20% to 80% Incident Wave Rise Time: 300 ps
- Waveform Digitizing Resolution: 5 ps
- SDI-12 Interface
- 3-element 5 cm stainless steel waveguide
- 5m or 10m 3-conductor waterproof cable (standard)
- Waterproof Epoxy-filled Housing
Measurement Functions
- Volumetric Water Content: 0% to 100%
- Medium Permittivity: 1 to 85
- Medium Bulk Electrical Conductivity: 0 to 6000 µS/cm
- Medium Temperature: -40 to +55 degrees C
- Pore Water EC (Hilhorst Model): 0 to 55000 µS/cm
Measurement Performance
Parameter | Min | Max | Units |
RELATIVE PERMITTIVITY | |||
Range | 1 | 85 | – |
Resolution | 0.1 | – | |
Repeatability (RMS deviation) | 0.21 | – | |
Accuracy | -4 | +4 | %FS[1] |
Stability with Bulk Electrical Conductivity (0-6000 uS/cm) | -1 | +1 | %FS |
VOLUMETRIC WATER CONTENT (VWC) | |||
Range[2] | 0 | 100 | % |
Resolution | 0.1 | % | |
Repeatability (RMS deviation) | 0.5 | % | |
Accuracy | -5 | +5 | %FS |
Stability with Bulk Electrical Conductivity (0-6000 uS/cm) | -1 | +1 | %FS |
TEMPERATURE[3] | |||
Range | -40 | +55 | °C |
Resolution | 0.1 | °C | |
Repeatability (RMS deviation) | 0.01 | °C | |
Accuracy (+5 to +35 °C) | -0.25 | +0.25 | °C |
Accuracy (-15 to +55 °C) | -0.5 | +0.5 | °C |
BULK ELECTRICAL CONDUCTIVITY (BEC) | |||
Range | 0 | 6000 | uS/cm |
Resolution | 1 | uS/cm | |
Repeatability (RMS deviation) | 3 | uS/cm | |
Accuracy (0 – 1000 uS/cm) | -25 | +25 | uS/cm |
Accuracy (1000 – 2500 uS/cm) | -2.5 | +2.5 | % |
Accuracy (2500 – 6000 uS/cm) | -5 | +5 | % |
1. Percent Full scale, i.e., +/- 2 percentage points.
2. VWC is calculated based on relative permittivity using the formula derived by Topp with minor modifications toallow readings in slurries and pure water. The relative permittivity of water varies with temperature, so to see a reading near 100%, the sensor must be fully immersed in water long enough to equilibrate temperature with the water. The water should be at 20.5C with at least 4cm of water around the rods on all sides, beyond the tips of the
rods, and at least 1cm of the sensor body immersed. VWC readings higher than 100% are possible when the permittivity is higher than 80.
3.The temperature sensing element is located next to one of the outer waveguide electrodes.
Absolute Maximum Ratings
Stresses beyond those specified below may cause permanent damage to the sensor. These are stress ratings only and operation at these levels is not implied.
Parameter | Min | Max | Units |
Supply Voltage (Measured between the red and white wires) | -16 | +16 | Volts |
SDI-12 Data Voltage (Blue-White wires) | -16 | +16 | Volts |
External Voltage Applied to sensor rod | -0.3 | +4 | Volts |
Electrostatic discharge, center rod | IEC 61000−4−2 (ESD) | ||
Storage Temperature | -40 | +60 | °C |
-40 | +140 | °F |
Operating Conditions
Parameter | Min | Max | Units |
Operating Supply Voltage (Prior to 2H 2022) |
+4.2 (+6.5) |
+15 | Volts |
Operating Temperature (VWC errors due to ice) | -30 | +55 | °C |
Operating Temperature (VWC accurate, no ice allowed) | 0 | +55 | °C |
POWER CONSUMPTION | |||
Idle Current (sensor powered but inactive, 20 °C) | < 10 | uA | |
Idle Current (-35 to +50 °C) | < 50 | uA | |
Sensor read time | 0.4 typical | sec | |
Sensor read current (Supply Voltage = 12V) | 118 typical | mA | |
Sensor read current (Supply Voltage = 7V) | 150 typical | mA | |
Sensor communications current | 6 typical | mA |
SDI-12 Data Line Electrical Characteristics
Parameter | Min | Max | Units |
INPUT (when sensor is idle or receiving data) | |||
Resistance to GND | 160k | 175k | Ohms |
VIL (required input voltage in “marking” state) | -1 | 1.3 | V |
VIH (required input voltage in “spacing” state) | 3.2 | 6 | V |
OUTPUT (when sensor is transmitting data) | |||
Output impedance | 1000 | 1250 | Ohms |
VOL (output voltage in “marking” state) | 0 | 0.25 | V |
VOH (output voltage in “spacing” state) | 4.7 | 5.2 | V |
Physical Characteristics
Dimensions (without cable) | 15 cm x 3.3 cm |
Weight (without cable) | 121 g |
Cable weight | 32.7 g/m |
Composition | 316 Stainless Steel, Epoxy, ABS Plastic |
Cable | 3 copper conductor, 22 Ga., waterproof and UV resistant PVC jacket, 4.8mm overall diameter |
Communication Protocol | SDI-12 Version 1.4 |
This Product does not include Tax and shipping costs. International shipping is subject to regulations and Import Taxation of Country of destination.
Tel: (+506) 7037-8077 or Toll Free: 1(800) 2130227
Solar Systems in United States & Latin America